Configure RPC connection settings
Jump to overview

Policy overview

Key metadata and intent for this policy.

Computer
Category
Printers
Supported on
At least Windows Server 2016, Windows 10

Supported OS tags: Windows10, Windows10RT, Windows11, WindowsServer2016

This policy setting controls which protocol and protocol settings to use for outgoing RPC connections to a remote print spooler. By default, RPC over TCP is used and authentication is always enabled. For RPC over named pipes, authentication is always enabled for domain joined machines but disabled for non domain joined machines. Protocol to use for outgoing RPC connections: -- "RPC over TCP": Use RPC over TCP for outgoing RPC connections to a remote print spooler -- "RPC over named pipes": Use RPC over named pipes for outgoing RPC connections to a remote print spooler Use authentication for outgoing RPC over named pipes connections: -- "Default": By default domain joined computers enable RPC authentication for RPC over named pipes while non domain joined computers disable RPC authentication for RPC over named pipes -- "Authentication enabled": RPC authentication will be used for outgoing RPC over named pipes connections -- "Authentication disabled": RPC authentication will not be used for outgoing RPC over named pipes connections If you disable or do not configure this policy setting, the above defaults will be used.

Internal name
ConfigureRpcConnectionPolicy
Policy ID
3a23c77e4527
Elements
2

Registry values

How enabled and disabled states update the registry.

No explicit registry values are set for enabled or disabled states.

Policy elements

Inputs and configuration options exposed by this policy.

ScopeElementTypeRegistry mappingConstraints & behaviorCopy
Computer
Protocol to use for outgoing RPC connections:
ID RpcConnectionProtocol_Enum
enum
Path
Software\Policies\Microsoft\Windows NT\Printers\RPC
Value name
RpcUseNamedPipeProtocol
Type
REG_DWORD
Options: RPC over TCP (0), RPC over named pipes (1)
Computer
Use authentication for outgoing RPC connections:
ID RpcConnectionAuthentication_Enum
enum
Path
Software\Policies\Microsoft\Windows NT\Printers\RPC
Value name
RpcAuthentication
Type
REG_DWORD
Options: Default (0), Authentication enabled (1), Authentication disabled (2)
Protocol to use for outgoing RPC connections:
Computer · Type enum
Registry mapping
Path
Software\Policies\Microsoft\Windows NT\Printers\RPC
Value name
RpcUseNamedPipeProtocol
Type
REG_DWORD
Details
Options: RPC over TCP (0), RPC over named pipes (1)
Use authentication for outgoing RPC connections:
Computer · Type enum
Registry mapping
Path
Software\Policies\Microsoft\Windows NT\Printers\RPC
Value name
RpcAuthentication
Type
REG_DWORD
Details
Options: Default (0), Authentication enabled (1), Authentication disabled (2)